- Zeobercom
- China
● 2-channel CAN bus communication
● Max baud rate: 1Mbps
● CAN2.0A/B agreement supported
● Optional terminal resistance
● 16-channel bidirectional TTL electric level digital I/O
Product Description
ZY35201/35301/35401/35501 is a bus interface module with 2-channel CAN based on PXI/CPCI/PCI/PC104+/PC104 bus respectively which supports CAN2.0A and CAN2.0B agreement.
There are 2 communication channels of CAN and the following sheet is about the input and output:
Symbol | Parameter | Min | Max |
VIH | Input High Level | 0.7VCC | VCC+0.3V |
IIH | Input High Current | -200 | +30uA |
VIL | Input Low Level | -0.3V | 0.3VCC |
IIL | Input Low Current | -100 | -600 uA |
VOH | Output High Level | 2.75V | 4.5V |
VOL | Output Low Level | 0.5V | 2.25V |
16-channel bidirectional TTL electric level digital I/O
the following sheet is about the input and output:
Symbol | Parameter | Min | Max |
VIH | Input High Level | 2V | - |
IOH | High lever output Current | - | -24mA |
VIL | Input Low Level | - | 0.8V |
IOL | Low lever output Current | - | 24mA |
VIB | Input Voltage | - | 5V |
VOB | Output Voltage | - | 5V |
Δt/Δv | Input transition fall or rise time | - | 10ns/V |
Performance Parameters
Quantity of channels ........... 2
The maximum transmission rate ........... 1Mb/s
General Specifications
External dimensions (L×W×H) ........... Standard PXI/CPCI 3U card 160mm×100mm× 4HP, tolerance<0.2mm, with 3U puller, standard PCI card 175mm×106mm, tolerance<0.2mm, standard PC104 card 96mm×90mm, tolerance<0.2mm
Connector ........... DB37 pinhole connector
Working Environment
Temperature range ........... -20℃ ~ +60℃
Relative humidity ........... 5~ 90%, no condensation
Typical Applications
Expand the quantity of series ports
Signal data acquisition
Industrial control
CAN Bus Interface Module
CAN bus interface module is based on PXI/CPCI/PCI/PC104 bus. Our 2-channel/20-channel communication support CAN2.0A/B protocol with baud rate up to 1Mbps. In addition, we can also provide modules with Windows, Linux, Lab VIEW/RT, RTX, QNX module driver and API and customized ICD software. This module can be widely used in expanding the quantity of serial ports, collecting signal data and Industrial controlling etc.
Selection Guide for CAN Bus Interface Modules
Model No. | Type | Bus type | Channel | Isolation | Communication rate | Terminal resistance access | Send FIFO | Receive FIFO | Electric level standard |
ZY35201 | communication interface/CAN | PXI/CPCI | 2 | channel isolation | 1M | optional | 64K×32BIT | 1M×32BIT | CAN2.0 |
ZY35251 | communication interface/CAN | PXI/CPCI | 20 | channel isolation | 1M | optional | 64K×32BIT | 1M×32BIT | CAN2.0 |
ZY35301 | communication interface/CAN | PCI | 2 | channel isolation | 1M | optional | 64K×32BIT | 1M×32BIT | CAN2.0 |
ZY35351 | communication interface/CAN | PCI | 20 | channel isolation | 1M | optional | 64K×32BIT | 1M×32BIT | CAN2.0 |
ZY35401 | communication interface/CAN | PC104+ | 2 | channel isolation | 1M | optional | 64K×32BIT | 1M×32BIT | CAN2.0 |
ZY35501 | communication interface/CAN | PC104 | 2 | channel isolation | 1M | optional | 64K×32BIT | 1M×32BIT | CAN2.0 |